Phase-failure relays

ЕЛ-11М and ЕЛ-11М2 phase-failure relays

Phase-failure relays

Purpose:Phase-failure relays monitor the state of a three-phase network and protect the load against impermissible voltage deviations in one or more phases (phase imbalance or asymmetry), a change in phase sequence, and the loss of one or more phases.

ЕЛ-11М

Distinctive features:
  • Microprocessor control with digital signal processing. No adjustment required.
  • Monitoring of phase loss and phase sequence.
  • Phase imbalance monitoring.
  • Umin monitoring.
  • Adjustable switch-off delay when the voltage falls below Umin.
  • Hysteresis on re-closing.
  • Output status shown on a bi-colour LED.
  • Powered from the monitored network.
  • Versions for nominal phase voltages of 220 V and 127 V.
  • Galvanically isolated normally closed and normally open contacts.
    Switching life at least 3×107.
  • DIN-rail mounting, 35 mm case.

Technical specifications:
  • Power consumption, max: 4 W
  • Mains frequency, (48 – 62) Hz
  • Operating voltage, 380/220 V
  • Maximum switched current for a resistive load — 8 A
  • Maximum switched AC voltage — 250 V
  • Overall dimensions, 86×35×60 mm
  • Weight, max, 200 g.
  • Operating temperature range (-25 – +55) °C
  • Storage temperature, (-40 – +70) °C
  • Timing accuracy: better than ±5%
  • Climatic category УХЛ
  • Mounting method and method of connecting external leads:
    - for DIN-rail mounting;
    - supply conductors connected via terminal blocks.


Datasheet for the ЕЛ11М phase-failure relay


ЕЛ-11М2

Distinctive features:
  • Microprocessor control with digital signal processing.
  • No adjustment required.
  • Phase loss monitoring.
  • Phase sequence monitoring.
  • Phase imbalance monitoring.
  • Umin and Umax monitoring
  • Neutral conductor break monitoring.
  • Switch-off delay when the voltage falls below Umin or rises above Umax.
  • Hysteresis (reset ratio) on re-closing.
  • Input and output status shown on a bi-colour LED.
  • Powered from the monitored network.
  • Two groups of isolated changeover contacts
  • DIN-rail mounting, narrow case (35 mm).
  • Voltage setpoints, hysteresis and operating time can all be changed in software.

Technical specifications:
  • Monitored circuit connection: three phases with neutral.
  • Nominal operating voltage 380/220 V
  • Mains frequency, 48 - 62 Hz
  • Upper pickup threshold — 264 V
  • Lower pickup threshold — 165 V
  • Hysteresis, 10 V
  • Pickup delay on Umin, and on loss of a phase — 1 s
  • Pickup delay on Umax, and on complete loss of voltage on all three phases — 0.15 s
  • Pickup delay on a change of phase sequence — 0.1 s
  • Active power consumption, max: 3 W
  • Insulation voltage input-to-contact and contact-to-contact — 1000 V
  • Overall dimensions, 90×65×35 mm
  • Weight, max, 200 g
  • Operating temperature range (-25 – +55) °C
  • Voltage pickup accuracy better than ±3%
  • Delay timing accuracy: better than ±5%
  • Climatic category УХЛ
  • Protection rating IP20
  • Mounting method and method of connecting external leads:
    for DIN-rail mounting; supply conductors connected via terminal blocks
  • The terminals accept external conductors of at least 1.5 mm².


Datasheet for the ЕЛ11М2 phase-failure relay